RELIABILITY TEST CONDITIONS
SMT WOUND CHIP INDUCTORS TYPE
FOR SMD322522/453232 / SMTSDR322520/453226 / SMDCHGR0603/0805/1008/1210 / SMDFSR1008 / SMTS |
| Item (項目) |
Required Characteristics (要求) |
Test Method/Condition (測試方法) |
High temperature Storage test
Reference documents:
MIL-STD-202G Method 108A
高溫儲存試驗 |
1.No case deformation or
change in appearance.
2.
ΔL/L≦30%(close magnetic circui)ΔL/L≦10%
3.ΔQ/Q≦30%
4.ΔDCR/DCR≦10%
1.無明顯的外觀缺陷
2.感值變化不超過10%(封閉磁路)
感值變化不超過10%
3.品質因數變化不超過30%
4.直流電阻變化不超過10% |
Temperature: 85±2 °C Time : 96±2 hours
Tested not less than 1 hour, nor more than 2 hours at room temperature.

溫度: 85±2 °C,時間: 96±2,小時樣品在室溫
下放置1小時,
不 超2小時間必須測試. |
Low temperature Storage test
Referencedocuments:
IEC 68-2-1A 6.1 6.2
低溫儲存試驗 |
1.No case deformation or
change in appearance.
2. ΔL/L≦30%(close magnetic circui)ΔL/L≦10%
3.ΔQ/Q≦30%
4.ΔDCR/DCR≦10%
1.無明顯的外觀缺陷
2.感值變化不超過10%(封閉磁路)
感值變化不超過10%
3.品質因數變化不超過30%
4.直流電阻變化不超過10% |
Temperature: -25±2°C Time : 96±2 hours
Tested not less than 1 hour, nor more than 2 hours at room temperature.

溫度: -25±2°C,時間:96±2,小時
樣品在室溫下放置1小時,不超2小
時間必須測試.
|
Humidity test Reference
documents: MIL-STD-202G Method 103B
濕度測試 |
1.No case deformation or
change in appearance.
2. ΔL/L≦30%(close magnetic circui)ΔL/L≦10%
3.ΔQ/Q≦30%
4.ΔDCR/DCR≦10%
1.無明顯的外觀缺陷
2.感值變化不超過10%(封閉磁路)
感值變化不超過10%
3.品質因數變化不超過30%
4.直流電阻變化不超過10%
|
1. Dry oven at a temperature of 40° ±5°C
for 24 hours.
2. Measurements At the end of this period
3. Exposure:Temperature: 40±2°C , Humidity: 93±3%RH Time : 96±2 hours
4. Tested while the specimens are still in the chamber
5. Tested not less than 1 hour, nor more
than 2 hours at room temperature.

1.樣品必須先在40° ±5°條件下乾燥24小時
2.乾燥後測試
3.暴露: 溫度:40±2°C , 濕度: 93±3%RH 時間 :
96±2 hours
4.暴露結束後,在試驗箱中進行測試.
5.樣品在室溫下放置1小時,不超2小
時間必須測試.
|
Thermal shock test
Reference documents:
MIL-STD-202G Method 107G
熱衝擊測試 |
1.No case deformation or
change in appearance.
2. ΔL/L≦30%(close magnetic circui)ΔL/L≦10%
3.ΔQ/Q≦30%
4.ΔDCR/DCR≦10%
1.無明顯的外觀缺陷
2.感值變化不超過10%(封閉磁路)
感值變化不超過10%
3.品質因數變化不超過30%
4.直流電阻變化不超過10% |
First -40°CforT time, last125°CT time as
1 cycle. Go through 20 cycles.

從-40°C作用T分鐘,然後溫度衝擊到125°C
作用T分鐘, 作為一個循環,共作用20次. |